SOLICITATION DETAILS
Solicitation Details
Type: | Request For Qualifications (RFQS) |
---|---|
Status: | Closed |
Solicitation Number: | RFQS 6100 CLMP343 |
Description: | Southwest Parkway TM and Elevated Reservoir / South I-35 Ele |
Summary: | The objective of the projects is to increase storage capacity in the distribution system, through the design and commissioning of transmission mains, associated elevated storage reservoirs, and associated piping and accessories, thereby improving reliability and level of service for existing and future customers. The transmission mains and associated elevated reservoirs will help ensure adequate pressures are maintained in the system, while also adding surge protection and improving pumping efficiency. Conceptually, the Southwest Parkway Elevated Reservoir project consists of approximately 10,300 LF of 24-inch transmission main that extends along Southwest Parkway, Old Bee Caves Road, and Travis Cook Road and a 2-million-gallon elevated reservoir, located at Southwest Parkway near Amarra Lane. Additionally, the South I-35 Elevated Reservoir project is planned as a 3-million-gallon elevated reservoir, located along the South I-35 Southbound Service Road, with foundational piping for a future pump station tie-in. |
Estimated Amount for Solicitation: |
Subcontracting Goals
African American | 0.86% |
---|---|
Hispanic American | 4.88% |
Native/Asian American | 3.60% |
WBE | 3.86% |
Contact Information
Authorized Contact Names: | |
---|---|
Project Related Questions: |
Christopher Irwin (512) 974-7332 chris.irwin@austintexas.gov |
Solicitation Specific Questions: |
Megan Bowles (512) 974-1404 megan.bowles@austintexas.gov |
Small Minority Business Resources Questions: |
Kenneth Kalu (512) 974-7621 smbrcompliancedocuments@austintexas.gov |
Dates, Times & Locations
Important Solicitation Dates: | |
---|---|
Solicitation Published: | 12/05/2022 09:41 AM |
Response Due: |
Prior to 01/17/2023, 02:00 PM Central Procurement, 505 Barton Springs Road, Suite 1350 Austin Texas 78704 |
Compliance Plan Due: | Prior to 01/17/2023 02:00 PM Required Required Central Procurement, 505 Barton Springs Road, Suite 1350 Austin Texas 78704 |
Vendor Meetings/Conference, Site Visits (Date/Time/Location): | |
---|---|
Meeting: |
12/12/2022, 10:00 AM
MS Teams |
Special Notes
Special Notes: |
Compliance Plan Required. |
---|
Packet Download Files
BIDDERS / PROPOSERS:
Listed below are the various documents that have been issued as part of this Solicitation. Each document contains specific information about the solicitation. We recommend that you view and/or download each document before preparing your response to the solicitation, and that you use the bid subscription link to record your interest in this solicitation.
Associated Commodities
Description | Code |
---|---|
Civil Engineering | 92517 |
Trade Summary
Description | Category | Code |
---|---|---|
Landscape Architecture | Professional | 90656 |
Surveying Services (Not Aerial Or Research) | Non-professional | 90779 |
Welding | Construction | 91485 |
Civil Engineering | Professional | 92517 |
Drainage Engineering | Professional | 92528 |
Environmental Engineering | Professional | 92535 |
Foundation Engineering | Professional | 92542 |
Geotechnical - Soils | Professional | 92546 |
Geotechnical Engineering | Professional | 9254640 |
Instrumentation/Engineering | Professional | 92557 |
Mechanical Engineering | Professional | 92567 |
Site Assessment | Professional | 92586 |
Structural Engineering | Professional | 92588 |
Traffic And Transportation Engineering | Professional | 92593 |
Permitting Services, Environmental | Non-professional | 92670 |
Cost Estimating | Non-professional | 96121 |
Environmental Impact Studies | Non-professional | 96132 |
Utility Locator Service (Underground) | Non-professional | 96291 |
Corrosion Control Services | Non-professional | 96825 |